The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the building.

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.


F.C.I.
64.36 %

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies approximately 20,400 different repairs needed in our schools. The total value of those repairs was $4.2 billion as of March 2023.

For the 2022-2023 school year, the TDSB  received $292 million in provincial funding. These funds will be used to replace/repair building components identified during the Ministry’s school inspections, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).
Brief DescriptionPriority
A101004 Standard Foundations Repairs - Damp proofing Repairs - Original Basement RenewalUrgent
A101004 Standard Foundations Repairs - Parging repairs RenewalUrgent
Distribution Systems - Steam Piping Distribution Systems RenewalUrgent
Main Switchboards - Switchgear - Pool RenewalUrgent
Roof Coverings - Section B,B1,B2,D RenewalUrgent
Air Distribution, Heating & Cooling - Duct System RenewalHigh
Air Handling Units - SF #1, #2 and #3 RenewalHigh
Auxiliary Equipment - Chemical Feed System RenewalHigh
Auxiliary Equipment - HVAC Pumps RenewalHigh
B101001 Structural Frame - Original Building Boiler Room RenewalHigh
B201014 Exterior Walls - Masonry Re-pointing RenewalHigh
Branch Wiring RenewalHigh
C301005 Wall Finishes - Paint - Older RenewalHigh
C302004 Floor Finishes - Vinyl Tile - Older RenewalHigh
C302007 Floor Finishes - Painted Sealed Concrete RenewalHigh
Ceiling Finishes - Fixed Acoustic Tile - Entire School RenewalHigh
Controls and Instrumentation - BAS RenewalHigh
Controls and Instrumentation - Pneumatic RenewalHigh
Cooling Generating Systems - Cool - Library RenewalHigh
Distribution Systems - Exhaust Systems - Axial RenewalHigh
Distribution Systems - Exhaust Systems - Centrifugal RenewalHigh
Domestic Water Distribution - Pipes and Fittings RenewalHigh
Domestic Water Distribution - Sump Pumps RenewalHigh
Exterior Doors - Hardware - Older RenewalHigh
Exterior Doors - Hollow Metal and Wood - Original RenewalHigh
Fencing & Gates - Chain link & Wrought Iron Fence RenewalHigh
Fencing & Gates - Wood Fence RenewalHigh
Fin Tube Radiation Units - Perimeter Heating RenewalHigh
Fittings - Millwork - Counter & Cabinet RenewalHigh
Floor Finishes - Hardwood RenewalHigh
Interior Doors - Hardware - Older RenewalHigh
Interior Doors - Wood & Hollow Metal - Older RenewalHigh
Interior Stair Construction - Metal Framed RenewalHigh
Lighting Equipment - Exterior - Wall RenewalHigh
Playing Fields - Soccer Field, Football and Baseball Diamond - Unpaved RenewalHigh
Retaining Walls - Wood RenewalHigh
Roof Coverings - Section A,A1,A2,A3,A4,A6,B3,F RenewalHigh
Roof Coverings - Section A5,B8 RenewalHigh
Sanitary Waste - Piping RenewalHigh
Signage RenewalHigh
Structural Frame - Addition 6 and Addition 7 RenewalHigh
C1010 Partitions - Localized Deficiencies RenewalMedium
C101003 Partitions - Moveable - Foldable Partition (GYM) RenewalMedium
C1030 - Fittings - Washroom RenewalMedium
C103009 Fittings - Millwork - Laboratories RenewalMedium
C302012 Floor Finishes - Porcelain RenewalMedium
Ceiling Finishes - Suspended Ceiling Tiles RenewalMedium
Domestic Water Distribution - Natural Gas DWH #1, #2 and #3 RenewalMedium
Pedestrian Paving - Asphalt and Concrete RenewalMedium
Pedestrian Paving - Interlocking Concrete Stone Walkways RenewalMedium
Stormwater Management - Grading & Catch Basins RenewalMedium
Ceiling Finishes - Plaster RenewalLow