Brief Description | Priority |
A101004 Standard Foundations Repairs - Parging repairs Renewal | Urgent |
C2010 Stair Construction - Metal framed and concrete framed - Aged Renewal | Urgent |
Roof Coverings - Section A,C,C1,C2,C3,D3 Renewal | Urgent |
Auxiliary Equipment - Chemical Feed Systems Renewal | High |
B201011 Exterior Walls - Joint Sealant Renewal | High |
B203004 Exterior Doors - Overhead Renewal | High |
C1030 - Fittings - Washroom Renewal | High |
C103009 Fittings - Millwork - Classrooms Renewal | High |
C2020 Stair Finishes - Anti-skid tape - Older Renewal | High |
C302004 Floor Finishes - Vinyl Tile - Older Renewal | High |
Ceiling Finishes - Suspended Acoustic Panel Ceiling Renewal | High |
Cooling Generating Systems - CU #1 and #2 Renewal | High |
Distribution Systems - Exhaust Systems - Axial Renewal | High |
Elevators and Lifts - Passenger - Hydraulic Renewal | High |
Exterior Doors - Hardware Renewal | High |
Exterior Doors - Older Renewal | High |
Exterior Windows - Original Building Renewal | High |
Fencing & Gates - Chain Link Fence & Flagpole Renewal | High |
Floor Finishes - Carpet Renewal | High |
Floor Finishes - Sheet Vinyl Renewal | High |
Interior Doors - Hardware - Older Renewal | High |
Interior Doors - Older Renewal | High |
Main Switchboards - Switchgear Renewal | High |
Parking Lots - Original Building Renewal | High |
Pedestrian Paving - Asphalt Paved - Site Renewal | High |
Plumbing Fixtures - Bradley Basins Renewal | High |
Roadways - Asphalt Paved - Site Renewal | High |
Roof Top AHU - Heat & Cool - HVAC #1 Thru #7 Renewal | High |
Secondary - Original Secondary Transformers Renewal | High |
Site Civil/Mechanical Utilities - Site Renewal | High |
Wall Finishes - Painted Renewal | High |
Auxiliary Equipment - Expansion Tanks Renewal | Medium |
Auxiliary Equipment - HVAC Pumps Renewal | Medium |
Branch Wiring Renewal | Medium |
C1010 Partitions - Localized deficiencies Renewal | Medium |
C101003 Partitions - Moveable - Foldable Partition (Classroom) - Atrium Renewal | Medium |
C101003 Partitions - Moveable - Foldable Partition (GYM) Renewal | Medium |
Distribution Systems - Heated Water Distribution Systems - Piping System Renewal | Medium |
Exterior Windows - Additions Renewal | Medium |
Fittings - Bleachers Renewal | Medium |
Fittings - Millwork - Laboratories Renewal | Medium |
Floor Finishes - Hardwood-Older Renewal | Medium |
Plumbing Fixtures - Lavatories Renewal | Medium |
Plumbing Fixtures - Urinals Renewal | Medium |
Ceiling Finishes - Gypsum Board Ceiling Renewal | Low |
Cooling Generating Systems - DX Split - Daiken Renewal | Low |
D502006 Lighting and Branch Wiring - Stage Lighting Renewal | Low |
Distribution Systems - Exhaust Systems - Centrifugal Renewal | Low |
Domestic Water Distribution - Drinking Fountains and Coolers Renewal | Low |
Domestic Water Distribution - Pipes and Fittings Renewal | Low |
Exterior Doors - Addition Renewal | Low |
Floor Finishes - Quarry Tile Renewal | Low |
Sanitary Waste - Piping Renewal | Low |
Signage - Pedestal Mounted - Site Renewal | Low |
Stormwater Management Renewal | Low |