Facility Condition Index

2022 -2023

The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the building.

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.


F.C.I.
52.96 %

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies approximately 20,400 different repairs needed in our schools. The total value of those repairs was $4.2 billion as of March 2023.

For the 2022-2023 school year, the TDSB  received $292 million in provincial funding. These funds will be used to replace/repair building components identified during the Ministry’s school inspections, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).
Brief DescriptionPriority
Auxiliary Equipment - Stacks & Breaching RenewalUrgent
Auxiliary Equipment - Expansion Tanks RenewalUrgent
Auxiliary Equipment - HVAC Pumps RenewalUrgent
Electrical Service and Distribution - Secondary Transformers RenewalUrgent
Heat Generating - Electric Baseboard Heaters RenewalUrgent
Roof Coverings - Section F2 RenewalUrgent
Air Distribution, Heating & Cooling - Duct System RenewalHigh
Air Handling Units - SF #1 thru SF #6 RenewalHigh
B201011 Exterior Walls - Joint Sealant RenewalHigh
Branch Wiring - Cabling, Raceways & Bus Ducts RenewalHigh
C1030 - Fittings - Washroom RenewalHigh
C103009 Fittings - Millwork - Laboratories RenewalHigh
Ceiling Finishes - Suspended Acoustic Panel Ceilings RenewalHigh
Controls and Instrumentation - Pneumatic RenewalHigh
Distribution Systems - Exhaust Systems - Axial RenewalHigh
Distribution Systems - Exhaust Systems - Centrifugal RenewalHigh
Distribution Systems - Heated Water Distribution Systems - Piping System RenewalHigh
Domestic Water Distribution - Pipes and Fittings RenewalHigh
Exterior Doors - Hollow Metal RenewalHigh
Exterior Windows - Single Glazed RenewalHigh
Fencing & Gates - Chain Link Fence RenewalHigh
Fin Tube Radiation Units - Perimeter Heating RenewalHigh
Fittings - Millwork RenewalHigh
Fittings - Retractable Stage RenewalHigh
Floor Finishes - Carpet RenewalHigh
Lighting Equipment - Exterior - Pole RenewalHigh
Lighting Equipment - Exterior RenewalHigh
Other Special Systems and Devices - Dust Collector RenewalHigh
Parking Lots - Asphalt Paved Parking Lot RenewalHigh
Playing Fields - Asphalt Paved RenewalHigh
Playing Fields - Soccor & Baseball Field - Unpaved RenewalHigh
Plumbing Fixtures - Urinals RenewalHigh
Roadways - Asphalt Paved Roadway RenewalHigh
Sanitary Waste - Piping RenewalHigh
C1010 Partitions - Localized Deficiencies RenewalMedium
C101003 Partitions - Moveable - Foldable Partition (Classroom) RenewalMedium
C302004 Floor Finishes - Vinyl Tile RenewalMedium
Domestic Water Distribution - Drinking Fountains and Coolers RenewalMedium
Energy Supply System - Natural Gas RenewalMedium
Exterior Doors - Hardware RenewalMedium
Pedestrian Paving - Concrete RenewalMedium
Plumbing Fixtures - Lavatories RenewalMedium
Plumbing Fixtures - Water Closets RenewalMedium
Roof Coverings - Section CD1 RenewalMedium
Wall Finishes - Painted RenewalMedium
Exterior Doors - Automatic Door Devices RenewalLow
Landscaping RenewalLow
Retaining Walls - Concrete RenewalLow