Date Inspected | Location in School | Health & Safety Issue Observed | Class | Action Taken By | Date Action Taken | Details |
09/21/23 | Boiler Room - Rm #141 | extinguisher - tag missing or annual inspection more than 3 months overdue | A | Caretaker | 09/25/23 | Details |
09/21/23 | 101 | lighting in need of repair (maintenance issue) | A | Caretaker | 09/25/23 | Details |
09/21/23 | Boiler Room - Rm #141 | housekeeping, clutter, dust or dirt | A | Caretaker | 09/25/23 | Details |
09/21/23 | 109A Chemical Prep Room | household cleaners present (not TDSB approved) | B | Caretaker | 09/25/23 | Details |
10/23/23 | 117 | ceiling damaged (specify) | A | Caretaker | 10/23/23 | Details |
10/23/23 | Hallway | ceiling damaged (specify) | A | Caretaker | 10/23/23 | Details |
10/23/23 | Boiler Room - Rm #141 | unable to inspect (specify why if possible) | B | Caretaker | 10/23/23 | Details |
11/01/23 | 215 Language Office | extension cord/power bar - inappropriate use of extension cord/power bar (be specific) | B | Caretaker | 04/27/24 | Details |
11/01/23 | 205 Chemical Prep Room | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 233 Geography Office | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 223 History Office | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 214 | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 212 | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 210 | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 209 | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 211 | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 213 | combustible material being displayed that is not fire rated/treated | A | Caretaker | 04/02/24 | Details |
11/01/23 | 118 Design & Tech Workrooms | eyewash station required or in need of repair (specify) | A | Caretaker | 11/28/23 | Details |
11/01/23 | 205 Chemical Prep Room | inspections not up to date (specify equipment) | B | Caretaker | 04/27/24 | Details |
11/01/23 | 211 | extension cord/power bar - inappropriate use of extension cord/power bar (be specific) | B | Caretaker | 04/27/24 | Details |
11/01/23 | 104 | equipment damaged or improperly stored (specify) | B | Caretaker | 11/28/23 | Details |
11/01/23 | 104 | lighting in need of repair (maintenance issue) | A | Caretaker | 11/28/23 | Details |
11/01/23 | Fan Room #1 - above front foyer | guarding or shielding not in place | A | Caretaker | 11/28/23 | Details |
11/01/23 | Boiler Room - Rm #141 | ACM - yellow asbestos bags present (attach a photo and include the number of bags)) | A1 | Caretaker | 11/28/23 | Details |
11/01/23 | Boiler Room - Rm #141 | eyewash station required or in need of repair (specify) | A | Caretaker | 11/28/23 | Details |
11/01/23 | 211 | extension cord/power bar - inappropriate use of extension cord/power bar (be specific) | B | Caretaker | 04/27/24 | Details |
12/08/23 | Boiler Room - Rm #141 | temperature does not meet TDSB Guideline | A | Caretaker | 04/27/24 | Details |
12/08/23 | West Gym | temperature does not meet TDSB Guideline | A | Caretaker | 04/27/24 | Details |
02/23/24 | 116 Main Office | ceiling damaged (specify) | A | Caretaker | 02/26/24 | Details |
02/23/24 | 114 Music | ceiling tiles missing/loose | A | Caretaker | 02/26/24 | Details |
03/26/24 | Hallway | lighting in need of repair (maintenance issue) | A | Caretaker | 03/27/24 | Details |
03/26/24 | Hallway | ceiling tiles missing/loose | A | Caretaker | 03/27/24 | Details |
04/01/24 | 109A Chemical Prep Room | display(s) not within TDSB standards as outlined by OH&S and Standards & Compliance (ie; artwork, hanging displays, paper on walls) | B | Caretaker | 04/27/24 | Details |
04/01/24 | 104 | display(s) not within TDSB standards as outlined by OH&S and Standards & Compliance (ie; artwork, hanging displays, paper on walls) | B | Caretaker | 07/02/24 | Details |
04/01/24 | Fan Room #1 - above front foyer | display(s) not within TDSB standards as outlined by OH&S and Standards & Compliance (ie; artwork, hanging displays, paper on walls) | B | Caretaker | 04/08/24 | Details |
04/01/24 | 205 Chemical Prep Room | eyewash station required or in need of repair (specify) | A | Caretaker | 07/26/24 | Details |
04/01/24 | 144 Presentation Suite | display(s) not within TDSB standards as outlined by OH&S and Standards & Compliance (ie; artwork, hanging displays, paper on walls) | B | Caretaker | 07/26/24 | Details |
04/01/24 | 205 Chemical Prep Room | display(s) not within TDSB standards as outlined by OH&S and Standards & Compliance (ie; artwork, hanging displays, paper on walls) | B | Caretaker | 07/02/24 | Details |
05/15/24 | 118T woodshop | trip hazard (i.e. flooring, other materials) | A | Caretaker | 07/26/24 | Details |
05/15/24 | 118T woodshop | eyewash station required or in need of repair (specify) | A | Caretaker | 07/26/24 | Details |
06/17/24 | Boiler Room - Rm #141 | extinguisher - tag missing or annual inspection more than 3 months overdue | A | Caretaker | 06/21/24 | Details |
06/17/24 | 205 Chemical Prep Room | fume hood - improper use (not to be used for storage) | B | Caretaker | 06/21/24 | Details |
06/17/24 | 205 Chemical Prep Room | improper storage - heavy containers must be stored on lower shelving | B | Caretaker | 07/02/24 | Details |
06/17/24 | 205 Chemical Prep Room | fume hood - improper use (not to be used for storage) | A | Caretaker | 06/21/24 | Details |
06/17/24 | 205 Chemical Prep Room | extinguisher - tag missing or annual inspection more than 3 months overdue | A | Caretaker | 06/21/24 | Details |
06/17/24 | 241 fan room | extinguisher - tag missing or annual inspection more than 3 months overdue | A | Caretaker | 06/21/24 | Details |
06/17/24 | staff room | Names and Locations of Certified First Aiders on site | B | Caretaker | 07/26/24 | Details |
06/17/24 | 109A Chemical Prep Room | eyewash station required or in need of repair (specify) | A | Caretaker | 06/21/24 | Details |
06/17/24 | 109A Chemical Prep Room | extinguisher - tag missing or annual inspection more than 3 months overdue | A | Caretaker | 06/21/24 | Details |
06/17/24 | 104 | eyewash station required or in need of repair (specify) | A | Caretaker | 06/21/24 | Details |
06/17/24 | 118 Design & Tech Workrooms | damaged surface (ie: wall, ceiling, flashing, drywall, flooring, stairs) | A | Caretaker | 06/21/24 | Details |
06/17/24 | 118 Design & Tech Workrooms | eyewash station required or in need of repair (specify) | A | Caretaker | 06/21/24 | Details |
06/17/24 | 118 Design & Tech Workrooms | extinguisher - tag missing or annual inspection more than 3 months overdue | A | Caretaker | 06/21/24 | Details |
06/17/24 | Boiler Room - Rm #141 | door/access door (specify) | A | Caretaker | 06/21/24 | Details |
06/17/24 | Mech room | ACM - insulation material damaged, possible ACM | A1 | Caretaker | 06/21/24 | Details |
06/17/24 | Mech room | leaking/pooling/ponding of water or liquid (be as specific as possible) | A | Caretaker | 06/21/24 | Details |
06/17/24 | 216A Dark Room | extinguisher - tag missing or annual inspection more than 3 months overdue | A | Caretaker | 06/21/24 | Details |
06/17/24 | 216A Dark Room | ventilation (specify) | A | Caretaker | 06/21/24 | Details |
06/17/24 | Hallway | leaking/pooling/ponding of water or liquid (be as specific as possible) | A | Caretaker | 06/21/24 | Details |
06/17/24 | Exit 8 | window damaged, in need of repair (specify) | A | Caretaker | 06/21/24 | Details |
06/17/24 | Exit 8 | ceiling damaged (specify) | A | Caretaker | 06/21/24 | Details |
06/17/24 | 205 Chemical Prep Room | exposed wiring/damaged cord/ground pin missing | A | Caretaker | 06/21/24 | Details |