Toronto District School Board
Skip to main content

Roden Public School

Facility Condition Index

2022 -2023

The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the building.

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.


F.C.I.
41.27 %

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies approximately 20,400 different repairs needed in our schools. The total value of those repairs was $4.2 billion as of March 2023.

For the 2022-2023 school year, the TDSB  received $292 million in provincial funding. These funds will be used to replace/repair building components identified during the Ministry’s school inspections, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).
Brief DescriptionPriority
Roof Coverings - Section C,D to D3 RenewalUrgent
Air Handling Units - AHU #1 and #2 RenewalHigh
B201011 Exterior Walls - Joint Sealant RenewalHigh
Ceiling Finishes - Suspended RenewalHigh
Controls and Instrumentation - BAS RenewalHigh
Cooling Generating Systems - CU #1 and #2 RenewalHigh
Electrical Service and Distribution - Secondary Transformer (600V to 220/120) RenewalHigh
Exterior Doors - Hardware RenewalHigh
Exterior Doors - Steel & Wood RenewalHigh
Exterior Windows - Double Glazed RenewalHigh
Fencing & Gates - Chain Link & Wrought Iron Fence RenewalHigh
Fin Tube Radiation Units - Perimeter Heating RenewalHigh
Fittings - Millwork RenewalHigh
Floor Finishes - Carpet - Remaining Area RenewalHigh
G204001 Fencing and Gates - Wrought Iron Fencing RenewalHigh
G204002 Retaining Walls - Precast Concrete RenewalHigh
Lighting and Branch Wiring - Exterior Lighting - Wall Mounted RenewalHigh
Main Switchboards - Switchgear RenewalHigh
Playing Fields - Paved RenewalHigh
Playing Fields - Unpaved RenewalHigh
Retaining Walls RenewalHigh
Stormwater Management RenewalHigh
Structural Frame - Localized Deficiency RenewalHigh
C1010 Partitions - Localized Deficiencies RenewalMedium
C101003 Partitions - Moveable - Foldable Partition (Classroom) RenewalMedium
C101003 Partitions - Moveable - Foldable Partition (GYM) RenewalMedium
C1030 - Fittings - Washroom RenewalMedium
C103013 Fittings - Retractable Stage RenewalMedium
C302004 Floor Finishes - Vinyl Tile RenewalMedium
Distribution Systems - Exhaust Systems - Axial RenewalMedium
Domestic Water Distribution - DHW #1 and #2 RenewalMedium
Domestic Water Distribution - Drinking Fountains and Coolers RenewalMedium
Domestic Water Distribution - Pipes and Fittings RenewalMedium
Domestic Water Distribution - Water Storage Tank RenewalMedium
Electrical Service and Distribution - Panelboards RenewalMedium
Energy Supply System - Natural Gas Piping RenewalMedium
Interior Doors - Hardware RenewalMedium
Interior Doors - Wood RenewalMedium
Lighting and Branch Wiring - Branch Wiring - Cabling, Raceways & Bus Ducts Low Density RenewalMedium
Parking Lots - Asphalt RenewalMedium
Roof Coverings - Section D4 RenewalMedium
Wall Finishes - Painted RenewalMedium
Distribution Systems - Air Distribution, Heating & Cooling - Duct System RenewalLow
Fittings - Window Coverings RenewalLow
Pedestrian Paving - Asphalt RenewalLow
Plumbing Fixtures - Lavatories RenewalLow
Plumbing Fixtures - Urinals RenewalLow
Plumbing Fixtures - Water Closets RenewalLow
Sanitary Waste RenewalLow
Signage RenewalLow
Site Development - Exterior Stairs RenewalLow
Wall Finishes - Major Painting [LEEP] RenewalLow