Facility Condition Index

2022 -2023

The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the building.

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.


F.C.I.
66.80 %

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies approximately 20,400 different repairs needed in our schools. The total value of those repairs was $4.2 billion as of March 2023.

For the 2022-2023 school year, the TDSB  received $292 million in provincial funding. These funds will be used to replace/repair building components identified during the Ministry’s school inspections, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).
Brief DescriptionPriority
Auxiliary Equipment - Heat Exchanger - Shell & Tube - Pool RenewalUrgent
Auxiliary Equipment - Vaccum Return - SF 1A RenewalUrgent
Electrical Service and Distribution - Panelboards RenewalUrgent
Roof Coverings - Section A,A1,B,C,C1,D,E,E1,E2 RenewalUrgent
Sanitary Waste RenewalUrgent
Air Distribution, Heating & Cooling - Duct System RenewalHigh
Air Handling Units - Central AHUs RenewalHigh
C1030 - Fittings - Washroom RenewalHigh
C103009 Fittings - Millwork - Laboratories RenewalHigh
C302007 Floor Finishes - Painted Sealed Concrete RenewalHigh
Ceiling Finishes - Acoustic ceiling tiles RenewalHigh
Controls and Instrumentation - BAS RenewalHigh
Controls and Instrumentation - Pneumatic RenewalHigh
Domestic Water Distribution - Pipes and Fittings RenewalHigh
Domestic Water Distribution - Sump Pumps RenewalHigh
Exhaust Systems - Centrifugal RenewalHigh
Exterior Doors - Double Entrance Doors RenewalHigh
Exterior Doors - Hardware RenewalHigh
Exterior Windows - 1968 RenewalHigh
Fencing & Gates - Chain Link Fence RenewalHigh
Fin Tube Radiation Units - Perimeter Heating RenewalHigh
Fittings - Millwork RenewalHigh
Floor Finishes - Sheet Vinyl - Classrooms RenewalHigh
G204001 Fencing and Gates - Wrought Iron Fencing - RenewalHigh
Interior Doors - Hardware RenewalHigh
Interior Doors - Wooden and metal doors RenewalHigh
Interior Stair Construction - Steel framed stairs RenewalHigh
Lighting and Branch Wiring - Branch Wiring - Cabling, Raceways & Bus Ducts Low Density RenewalHigh
Lighting and Branch Wiring - Exterior Lighting - Pole Mounted RenewalHigh
Lighting and Branch Wiring - Exterior Lighting - Wall Mounted RenewalHigh
Main Switchboards - Switchgear RenewalHigh
Parking Lots - Asphalt RenewalHigh
Playing Fields - Asphalt paved RenewalHigh
Playing Fields - Baseball diamond and soccer field - Unpaved RenewalHigh
Plumbing Fixtures - Lavatories RenewalHigh
Rain Water Drainage RenewalHigh
Signage - School sign RenewalHigh
Wall Finishes - Painted RenewalHigh
C1010 Partitions - Localized Deficiencies RenewalMedium
C101003 Partitions - Moveable - Foldable Partition (Classroom) RenewalMedium
C302001 Floor Finishes - Ceramic RenewalMedium
Ceiling Finishes - Suspended acoustic ceiling tiles RenewalMedium
Fittings - Lockers RenewalMedium
Floor Finishes - Hardwood RenewalMedium
Floor Finishes - Vinyl Tile RenewalMedium
Pedestrian Paving - Asphalt and concrete paved RenewalMedium
Roadways - Asphalt RenewalMedium
Site Civil/Mechanical Utilities - Underground piping RenewalMedium
Fencing & Gates - Exterior stairs RenewalLow
Fittings - Aged drapes RenewalLow
Fittings - Permanent bleachers RenewalLow
G205007 Landscaping - Irrigation System RenewalLow
Landscaping - Planters and grassed areas RenewalLow
Parking Lots - Curbs RenewalLow
Playing Fields - Curbs - Paved RenewalLow