Brief Description | Priority |
Auxiliary Equipment - Circulation Pumps and Condensate Return Pumps Renewal | Urgent |
Distribution Systems - Heated Water Distribution Systems - Piping System Renewal | Urgent |
Electrical Service and Distribution - MCC and DP Renewal | Urgent |
Exterior Windows - Original Renewal | Urgent |
Site Civil Utilities - Underground Utilities Renewal | Urgent |
Standard Foundations Repairs - Damp proofing Repairs Renewal | Urgent |
Standard Foundations Repairs - Parging repairs Renewal | Urgent |
Air Distribution, Heating & Cooling - Ductwork Renewal | High |
Auxiliary Equipment - Expansion Tank - Hot Water Heating Loop Renewal | High |
Branch Wiring - 1950 Renewal | High |
C1010 Partitions - Localized Deficiencies Renewal | High |
C1030 - Fittings - Washroom Renewal | High |
C302002 Floor Finishes - Terrazzo - Epoxy Renewal | High |
C302004 Floor Finishes - Vinyl Tile Renewal | High |
Ceiling Finishes - Fixed Acoustic Tile - Original Building Renewal | High |
Controls and Instrumentation - BAS Renewal | High |
Cooling Generating Systems - Window AC Renewal | High |
Distribution Systems - Exhaust Systems - Axial Renewal | High |
Distribution Systems - Exhaust Systems - Centrifugal Renewal | High |
Domestic Water Distribution - Pipes and Fittings Renewal | High |
Domestic Water Distribution - Water Storage Tank Renewal | High |
Exterior Doors - Hardware - Older Renewal | High |
Exterior Doors - Older Renewal | High |
Exterior Walls - Joint Sealant Renewal | High |
Exterior Walls - Masonry Re-pointing Renewal | High |
Fencing & Gates - Chain Link - Site Renewal | High |
Fin Tube Radiation Units - Perimeter Heating Renewal | High |
Fittings - Millwork - 1927 & 1960 Building Renewal | High |
Floor Finishes - Hardwood - Gymnasium Renewal | High |
Floor Finishes - Painted Concrete - Mechanical Room Renewal | High |
Interior Doors - 1927 & 1960 Buildings - Wood and Metal Renewal | High |
Interior Doors - Hardware - 1927 & 1960 Buildings Renewal | High |
Lighting Equipment - Exterior - Pole Renewal | High |
Lighting Equipment - Exterior - Wall Renewal | High |
Plumbing Fixtures - Lavatories Renewal | High |
Plumbing Fixtures - Urinals Renewal | High |
Plumbing Fixtures - Water Closets Renewal | High |
Roadways - Asphalt - Site Renewal | High |
Roof Top AHU - Cool - RTU #3 Renewal | High |
Sanitary Waste - Piping Renewal | High |
Wall Finishes - Painted Renewal | High |
Air Handling Units - SF#1, #2, #3 Renewal | Medium |
Auxiliary Equipment - Blowdown and Condensate Renewal | Medium |
Auxiliary Equipment - Chemical Feed Systems Renewal | Medium |
Ceiling Finishes - Suspended Ceiling Tiles Renewal | Medium |
Cooling Generating Systems - DX Split AHU - Cool - CU #3 and #4 Renewal | Medium |
Cooling Generating Systems - DX Split AHU - Cool Renewal | Medium |
Exterior Doors - 1990 Building - Hollow Metal Renewal | Medium |
Floor Finishes - Terrazzo, Ceramic Renewal | Medium |
Heat Generating - Hot Water Boilers - #2 and #3 Renewal | Medium |
Heat Generating - Steam Boilers - #4 and #5 Renewal | Medium |
Hot Water Boilers - DHW Boiler #1 Renewal | Medium |
Interior Stair Construction - Original Building Renewal | Medium |
Pedestrian Paving - Concrete & Asphalt - Site - Paved Renewal | Medium |
Controls & Instrumentation - EMS Renewal | Low |
Exterior Doors - Automatic Device Renewal | Low |
Exterior Doors - Hardware - 1990 Building Renewal | Low |
Interior Doors - 1990 Building Renewal | Low |
Interior Doors - Hardware - 1990 Building Renewal | Low |
Interior Stair Construction - Interior Ramps Renewal | Low |
Other Special Systems and Devices - Dust Collector Renewal | Low |