Toronto District School Board
Skip to main content

Maurice Cody Junior Public School

Facility Condition Index

2022 -2023

The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the building.

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.


F.C.I.
49.85 %

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies approximately 20,400 different repairs needed in our schools. The total value of those repairs was $4.2 billion as of March 2023.

For the 2022-2023 school year, the TDSB  received $292 million in provincial funding. These funds will be used to replace/repair building components identified during the Ministry’s school inspections, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).
Brief DescriptionPriority
Auxiliary Equipment - Expansion Tanks RenewalUrgent
Auxiliary Equipment - HVAC Pumps RenewalUrgent
Auxiliary Equipment - Stacks & Breaching RenewalUrgent
Exterior Walls - Masonry Re-pointing RenewalUrgent
G204010 Site Development - Exterior Stairs - Concrete Exterior Stairs - New RenewalUrgent
Interior Stair Construction - All RenewalUrgent
Roof Coverings - Section A,A1 RenewalUrgent
Roof Coverings - Section B RenewalUrgent
Roof Coverings - Section D RenewalUrgent
Standard Foundations Repairs - Damp proofing Repairs RenewalUrgent
?G204001 Wrought Iron Fencing RenewalHigh
Air Distribution, Heating & Cooling RenewalHigh
Auxiliary Equipment - Heat Exchanger - Shell & Tube RenewalHigh
Branch Wiring RenewalHigh
C102007 Interior Doors - Hardware RenewalHigh
C103001 Fittings - Washroom Partitions - Water Closet RenewalHigh
C103002 Fittings - Washroom Accessories RenewalHigh
C302004 Floor Finishes - Vinyl Tile RenewalHigh
Elevators & Lifts RenewalHigh
Exterior Doors - Building (Except the 2011 Addition) - Hollow Metal RenewalHigh
Exterior Walls - Joint Sealant RenewalHigh
Exterior Windows - Original Remaining Wood RenewalHigh
Fittings - Millwork RenewalHigh
Floor Finishes - Carpet RenewalHigh
Floor Finishes - Cermaic Tile - Washrooms RenewalHigh
G202003 Parking Lots - Paved - Asphalt Paved RenewalHigh
G204001 Fencing and Gates - Chain Link Fence RenewalHigh
Lighting Equipment - Clock controlled high pressure Sodium RenewalHigh
Lighting and Branch Wiring - Exterior Lighting - Pole Mounted RenewalHigh
Plumbing Fixtures - Lavatories RenewalHigh
Plumbing Fixtures - Water Closets RenewalHigh
Retaining Walls - Cast-in-Place RenewalHigh
Site Civil/Mechanical Utilities RenewalHigh
Wall Finishes - Paint RenewalHigh
C101003 Partitions - Moveable - Foldable Partition (GYM) RenewalMedium
Ceiling Finishes - Lath & Plaster Ceiling RenewalMedium
Ceiling Finishes - Suspended Acoustic Panel Ceiling RenewalMedium
Domestic Water Distribution - Plumbing Piping System RenewalMedium
Electrical Service and Distribution - Panel (600, 220, 120 V) RenewalMedium
Floor Finishes - Painted/Sealed Concrete Floor RenewalMedium
Gas Supply System RenewalMedium
Interior Doors - Wood and Metal RenewalMedium
Landscaping RenewalMedium
Pedestrian Paving - Interlocking Concrete Paving Stones RenewalMedium
Roof Coverings - Section C RenewalMedium
Roof Coverings - Section AB1 to AB5 RenewalMedium
Standard Foundations - 1928 to 1935 RenewalMedium
Stormwater Management - Catch Basins RenewalMedium
Auxiliary Equipment - Chemical Feed System RenewalLow
Domestic Water Distribution - DWHs RenewalLow
Playing Fields - Asphalt Paved RenewalLow
Playing Fields - Playscape - Unpaved RenewalLow
Rain Water Drainage RenewalLow
Sanitary Waste RenewalLow
Signage RenewalLow