Oriole Park Junior Public School

Facility Condition Index

2022 -2023

The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the building.

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.


F.C.I.
74.28 %

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies approximately 20,400 different repairs needed in our schools. The total value of those repairs was $4.2 billion as of March 2023.

For the 2022-2023 school year, the TDSB  received $292 million in provincial funding. These funds will be used to replace/repair building components identified during the Ministry’s school inspections, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).
Brief DescriptionPriority
A101004 Standard Foundations Repairs - Damp proofing Repairs RenewalUrgent
Auxiliary Equipment - Blowdown RenewalUrgent
C2010 Stair Construction - Metal framed and concrete framed - Older RenewalUrgent
Distribution Systems - Steam Distribution Systems - Piping System RenewalUrgent
Roof Coverings - Section C,C1 RenewalUrgent
Roof Coverings - Section D1 RenewalUrgent
Air Handling Units - SF #1 RenewalHigh
B201014 Exterior Walls - Masonry Re-pointing RenewalHigh
C302004 Floor Finishes - Vinyl Tile RenewalHigh
Ceiling Finishes - Acoustic Tile Ceiling RenewalHigh
Distribution Systems - Air Distribution, Heating & Cooling - Duct System RenewalHigh
Distribution Systems - Exhaust Systems - Centrifugal RenewalHigh
Domestic Water Distribution - Drinking Fountains and Coolers RenewalHigh
Domestic Water Distribution - Pipes and Fittings RenewalHigh
Exterior Doors - Hardware RenewalHigh
Exterior Walls - Original Building RenewalHigh
Exterior Windows - OlderHigh
Fencing & Gates - Site RenewalHigh
Fin Tube Radiation Units - Perimeter Heating RenewalHigh
Fittings - Millwork RenewalHigh
Interior Doors - Fire Rated Doors - Exits 1,2,4High
Interior Doors - Hardware RenewalHigh
Interior Doors - Original Building RenewalHigh
Lighting Equipment - Exterior - Wall RenewalHigh
Main Switchboards - Switchgear RenewalHigh
Parking Lots - Asphalt Paved - Site RenewalHigh
Playing Fields - Unpaved RenewalHigh
Rain Water Drainage RenewalHigh
Terminal and Package Units - Unit Ventilators RenewalHigh
Underground Utilities - Site RenewalHigh
Wall Finishes - Painted RenewalHigh
Auxiliary Equipment - HVAC Pumps RenewalMedium
Auxiliary Equipment - Vacuum Return RenewalMedium
B308020 Exterior Soffits RenewalMedium
Branch Wiring RenewalMedium
C1010 Partitions - Localized deficiencies RenewalMedium
C1030 - Fittings - Washroom RenewalMedium
Ceiling Finishes - Plaster & Gypsum Board Ceiling RenewalMedium
Plumbing Fixtures - Bradley Basins RenewalMedium
Plumbing Fixtures - Lavatories RenewalMedium
Plumbing Fixtures - Urinals RenewalMedium
Plumbing Fixtures - Water Closets RenewalMedium
Auxiliary Equipment - Chemical Feed System RenewalLow
Controls and Instrumentation - BAS RenewalLow
Domestic Water Distribution - Natural Gas DWH RenewalLow
Floor Finishes - Ceramic Tile RenewalLow
Pedestrian Paving - Asphalt Paved - Site RenewalLow
Playing Fields - Asphalt Paved - Site RenewalLow
Stormwater Management - Site RenewalLow
Wall Finishes - Ceramic Wall Tile RenewalLow