Humberwood Downs Junior Middle Academy

Facility Condition Index

2022 -2023

The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the building.

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.


F.C.I.
44.43 %

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies approximately 20,400 different repairs needed in our schools. The total value of those repairs was $4.2 billion as of March 2023.

For the 2022-2023 school year, the TDSB  received $292 million in provincial funding. These funds will be used to replace/repair building components identified during the Ministry’s school inspections, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).
Brief DescriptionPriority
Roof Coverings - Section B to B5, D,D1,D2,E,E1,E3,E4,E5 RenewalUrgent
Auxiliary Equipment - Variable Frequency Drives (VFD) RenewalHigh
Controls and Instrumentation - BAS RenewalHigh
Domestic Water Distribution - DHW Pumps RenewalHigh
Domestic Water Distribution - DHW Storage Tanks RenewalHigh
Exterior Doors - Metal RenewalHigh
Exterior Walls - Localized Deficiency RenewalHigh
Floor Finishes - Carpet RenewalHigh
Playing Fields - Paved RenewalHigh
Standard Foundations - Localized Deficiency RenewalHigh
Air Distribution, Heating & Cooling - Duct Work RenewalMedium
Auxiliary Equipment - Chemical Feed Systems RenewalMedium
Auxiliary Equipment - Condensate Tank RenewalMedium
Auxiliary Equipment - Expansion Tanks RenewalMedium
Auxiliary Equipment - HVAC Pumps RenewalMedium
Auxiliary Equipment - Heat Exchanger - Plate RenewalMedium
Chilled Water Systems - CLG Tower RenewalMedium
Concrete Exterior Stairs RenewalMedium
Cooling Generating Systems - DX Split RenewalMedium
Domestic Water Distribution - Eyewash Stations RenewalMedium
Elevators and Lifts - Passenger - Hydraulic RenewalMedium
Exhaust Systems - Centrifugal RenewalMedium
Exterior Doors - Hardware RenewalMedium
Fittings - Washroom Partitions RenewalMedium
Floor Finishes - Hardwood RenewalMedium
Floor Finishes - Vinyl Tiles RenewalMedium
Heating Units - Forced Flow and Reheat RenewalMedium
Lighting and Branch Wiring - Exit Lighting and Signs RenewalMedium
Lighting and Branch Wiring - Exterior Lighting - Pole Mounted RenewalMedium
Lighting and Branch Wiring - Exterior Lighting - Wall Mounted RenewalMedium
Lighting and Branch Wiring - Interior Lighting RenewalMedium
Lighting and Branch Wiring - Stage Lighting RenewalMedium
Parking Lots RenewalMedium
Roadways - Paved RenewalMedium
Wall Finishes - Painted RenewalMedium
Domestic Water Distribution - Drinking Fountains and Coolers RenewalLow
Emergency Lighting & Power - Diesel Generator RenewalLow
Exterior Doors - Automatic Door Device RenewalLow
Fittings - Blinds RenewalLow
Fittings - Dust Collector RenewalLow
Interior Doors - Hardware RenewalLow
Landscaping RenewalLow
Other Special Systems and Devices - Dust Collector - Medium RenewalLow
Pedestrian Paving RenewalLow
Pedestrian Paving RenewalLow
Playing Fields - Playscapes - Unpaved RenewalLow
Plumbing Fixtures - Bradley Basins RenewalLow
Plumbing Fixtures - Lavatories RenewalLow
Plumbing Fixtures - Urinals RenewalLow
Plumbing Fixtures - Water Closets RenewalLow
Stair Finishes RenewalLow

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.